<?xml version="1.0" encoding="iso-8859-1" standalone="no"?>

<GmsArticle>
  <MetaData>
    <Identifier>hta000036</Identifier>
    <ArticleType>HTA-Kurzfassung</ArticleType>
    <TitleGroup>
      <Title language="de">Erkennungsg&#252;te und Kosteneffektivit&#228;t von Screeningverfahren zur Erfassung von prim&#228;ren Offenwinkelglaukomen</Title>
      <TitleTranslated language="en">Validity and cost-effectiveness of methods for screening of primary open angle glaucoma </TitleTranslated>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>Antony</Lastname>
          <LastnameHeading>Antony</LastnameHeading>
          <Firstname>Katja</Firstname>
          <Initials>K</Initials>
          <AcademicTitle>Mag.</AcademicTitle>
        </PersonNames>
        <Address>&#214;BIG - &#214;sterreichisches Bundesinstitut f&#252;r Gesundheitswesen, Stubenring 6, 1010 Wien, Tel.: &#43;43-1-51561-259<Affiliation>&#214;BIG - &#214;sterreichisches Bundesinstitut f&#252;r Gesundheitswesen, Wien, &#214;sterreich</Affiliation></Address>
        <Email>antony&#64;oebig.at</Email>
        <Creatorrole corresponding="yes" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Genser</Lastname>
          <LastnameHeading>Genser</LastnameHeading>
          <Firstname>Dieter</Firstname>
          <Initials>D</Initials>
          <AcademicTitle>Dr.</AcademicTitle>
        </PersonNames>
        <Address>&#214;BIG - &#214;sterreichisches Bundesinstitut f&#252;r Gesundheitswesen, Stubenring 6, 1010 Wien, Tel.: &#43;43-1-51561-297<Affiliation>&#214;BIG - &#214;sterreichisches Bundesinstitut f&#252;r Gesundheitswesen, Wien, &#214;sterreich</Affiliation></Address>
        <Email>genser&#64;oebig.at</Email>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Fr&#246;schl</Lastname>
          <LastnameHeading>Fr&#246;schl</LastnameHeading>
          <Firstname>Barbara</Firstname>
          <Initials>B</Initials>
          <AcademicTitle>Mag.</AcademicTitle>
        </PersonNames>
        <Address>&#214;BIG - &#214;sterreichisches Bundesinstitut f&#252;r Gesundheitswesen, Stubenring 6, 1010 Wien, Tel.: &#43;43-1-51561-150<Affiliation>&#214;BIG - &#214;sterreichisches Bundesinstitut f&#252;r Gesundheitswesen, Wien, &#214;sterreich</Affiliation></Address>
        <Email>froeschl&#64;oebig.at</Email>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <MeshheadingList>
        <Meshheading>
          <MeshMainheading majorTopic="no">OCULAR HYPERTENSION</MeshMainheading>
        </Meshheading>
        <Meshheading>
          <MeshMainheading majorTopic="no">EARLY DIAGNOSIS</MeshMainheading>
        </Meshheading>
        <Meshheading>
          <MeshMainheading majorTopic="no">DIAGNOSTIC TECHNIQUES AND PROCEDURES</MeshMainheading>
        </Meshheading>
        <Meshheading>
          <MeshMainheading majorTopic="no">DIAGNOSTIC TECHNIQUES, OPHTHALMOLOGICAL</MeshMainheading>
        </Meshheading>
        <Meshheading>
          <MeshMainheading majorTopic="no">ECONOMICS</MeshMainheading>
        </Meshheading>
      </MeshheadingList>
      <SubjectheadingDDB>610</SubjectheadingDDB>
    </SubjectGroup>
    <DatePublishedList>
      <DatePublished>20070207</DatePublished>
      <DateRepublished>20070823</DateRepublished>
      <DateRepublished>20070823</DateRepublished>
    </DatePublishedList>
    <Language>germ</Language>
    <SourceGroup>
      <Journal>
        <ISSN>1861-8863</ISSN>
        <Volume>3</Volume>
        <JournalTitle>GMS Health Technology Assessment</JournalTitle>
        <JournalTitleAbbr>GMS Health Technol Assess</JournalTitleAbbr>
      </Journal>
    </SourceGroup>
    <ArticleNo>01</ArticleNo>
    <Correction>
      <DateLastCorrection>20070823</DateLastCorrection>
    </Correction>
  </MetaData>
  <OrigData>
    <Abstract language="de" linked="yes">
      <SubHeadline2>Gesundheitspolitischer Hintergrund</SubHeadline2>
      <Pgraph>Etwa 950.000 Personen in Deutschland sind an einem Glaukom (gr&#252;ner Star) erkrankt, nur bei etwa der H&#228;lfte der Betroffenen ist die Erkrankung diagnostiziert. &#196;rztliche Fachgesellschaften empfehlen ein Glaukomscreening gem&#228;&#223; Leitlinie, vom gemeinsamen Bundesausschuss <TextGroup><PlainText>(G-BA)</PlainText></TextGroup> wurde ein Screening zu Lasten der gesetzlichen Krankenversicherung (GKV) 2004 abgelehnt. </Pgraph>
      <SubHeadline2>Wissenschaftlicher Hintergrund</SubHeadline2>
      <Pgraph>Die Diagnostik des prim&#228;ren Offenwinkelglaukoms (POWG) beruht auf der Beurteilung der Papille, der retinalen Nervenfasern und des Gesichtsfeldes. Zu den wichtigsten Untersuchungen z&#228;hlen die ophthalmoskopische Untersuchung, die konfokale Scanning-Laser-Tomographie, die Scanning-Laser-Polarimetrie, die Untersuchung mit dem &#8222;Retinal Thickness Analyzer&#8220; (RTA) und die optische Koh&#228;renztomographie (OCT) sowie perimetrische Untersuchungen zur Erfassung von Gesichtsfeldausf&#228;llen (Standardperimetrie, Frequenzverdopplungstechnik, Blau-Gelb-Perimetrie). Der Augeninnendruck (intraokul&#228;rer Druck &#61; IOD) als wichtigster therapierbarer Risikofaktor kann mit Non-Kontakt- oder Applanationstonometrie gemessen werden. </Pgraph>
      <SubHeadline2>Fragestellung</SubHeadline2>
      <Pgraph>Der HTA-Bericht geht der Frage nach, welche medizinische Wertigkeit einzelne Untersuchungsmethoden bzw. Kombinationen dieser zur Entdeckung eines Glaukoms haben und ob diese f&#252;r einen Einsatz als Screeninguntersuchung in Deutschland aus medizinischer und &#246;konomischer Sicht zu bef&#252;rworten sind. </Pgraph>
      <SubHeadline2>Methodik</SubHeadline2>
      <Pgraph>Die systematische Literatursuche in 35 internationalen Datenbanken ergibt 2602 Zusammenfassungen. Nach einem zweiteiligen Selektionsprozess mit definierten Kriterien verbleiben 57 bewertete Artikel.</Pgraph>
      <SubHeadline2>Ergebnisse</SubHeadline2>
      <Pgraph>Die 55 medizinischen Volltexte behandeln am h&#228;ufigsten die Frequenzverdopplungstechnik, die konfokale Scanning-Laser-Tomographie und die Scanning-Laser-Polarimetrie. F&#252;r die Blau-Gelb-Perimetrie, die Tonometrie und die augenfach&#228;rztliche ophthalmoskopische Untersuchung liegen einzelne Arbeiten vor. Die Qualit&#228;t der Studien bez&#252;glich der Evidenz f&#252;r Screeningbedingungen ist &#252;berwiegend als niedrig einzustufen. Keine einzelne Methode erreicht ausreichend gute Sensitivit&#228;ts- und Spezifit&#228;tswerte und auch f&#252;r die Kombination von Methoden liegen nicht ausreichend gute Daten vor. Nur zwei Modellrechnungen zur Kosteneffektivit&#228;t von Screeninguntersuchungen k&#246;nnen identifiziert werden, &#246;konomische Bewertungen neuere Untersuchungsmethoden liegen nicht vor. Eine britische Studie ermittelt die Kosten je richtig-positive Diagnose und favorisiert eine Kombination von Ophthalmoskopie, Tonometrie und Perimetrie entweder nur f&#252;r Risikopatienten oder f&#252;r alle Patienten als Erstuntersuchung. Ein kanadischer HTA-Bericht ermittelt die Kosten pro vermiedenes Jahr Erblindung. Von der Einf&#252;hrung eines Glaukomscreenings (Ophthalmoskopie und Tonometrie als Erstuntersuchung) wird auf Grund der Datenlage und der Kosten abgeraten. </Pgraph>
      <SubHeadline2>Diskussion</SubHeadline2>
      <Pgraph>Aus den Arbeiten geht eindeutig hervor, dass zum Screening eine Kombination von Methoden eingesetzt werden muss, um akzeptable Sensitivit&#228;ts- und Spezifit&#228;tswerte zu erhalten. Derzeit kann aus medizinischer Sicht jedoch keine Kombination von Untersuchungsmethoden oder ein Algorithmus zum Glaukomscreening mit ausreichend hoher Evidenz empfohlen werden. Klare Aussagen zu der Kosteneffektivit&#228;t von Screeninguntersuchungen auf Glaukom sind aufgrund der publizierten Literatur f&#252;r Deutschland noch nicht zu treffen. </Pgraph>
      <SubHeadline2>Schlussfolgerungen</SubHeadline2>
      <Pgraph>Um die optimale Kombination von Methoden f&#252;r ein Glaukomscreening zu finden, m&#252;ssen populationsbasierte Longitudinalstudien durchgef&#252;hrt werden. Die Kosteneffektivit&#228;t von Screeninguntersuchungen auf Glaukom kann vor diesem Hintergrund noch nicht klar beurteilt werden. Die &#246;konomische Bewertung eines medizinisch effektiven Screeningpfads sollte auf die Effektma&#223;e Vermeidung von Sehbeeintr&#228;chtigung und Erblindung gerichtet sein.</Pgraph>
    </Abstract>
    <Abstract language="en" linked="yes">
      <SubHeadline2>Health political background </SubHeadline2>
      <Pgraph>About 950,000 people are affected by glaucoma in Germany, about 50&#37; of which are undiagnosed. The German Ophthalmological Society and the German Association of Ophthalmologists recommend a screening for glaucoma according to their guidelines. The Federal Joint Committee disapproved a glaucoma-screening program on expense of the compulsory health insurance in 2004. </Pgraph>
      <SubHeadline2>Scientific background</SubHeadline2>
      <Pgraph>Primary open angle glaucoma is diagnosed by evaluation of the optic disc, the retinal fibre layer and the visual field. The main examinations are ophthalmoscopy, scanning laser polarimetry, confocal scanning laser ophthalmoscopy, retinal thickness analysis and optical coherence tomography. Scotomas are diagnosed by perimetry (standard automated perimetry, short wavelength automated perimetry and frequency doubling perimetry). The intraocular pressure is the most important treatable risk factor and is measured by (contact or non-contact) tonometry. </Pgraph>
      <SubHeadline2>Research questions</SubHeadline2>
      <Pgraph>The aim of this HTA-report is to investigate the diagnostic validity and cost effectiveness of diagnostic techniques or combinations of these methods with respect to the use in a screening setting in Germany. </Pgraph>
      <SubHeadline2>Methods</SubHeadline2>
      <Pgraph>A systematic literature research was performed in 35 international databases and yielded 2602 articles. Overall 57 publications were included for assessment, according to predefined selection criteria. </Pgraph>
      <SubHeadline2>Results</SubHeadline2>
      <Pgraph>The 55 medical articles deal mainly with frequency doubling perimetry, confocal scanning laser ophthalmoscopy and scanning laser polarimetry. Few articles cover short wavelength automated perimetry, tonometry and ophalmocopic evaluations by ophthalmologists. The quality of the papers is generally low, as far as the evidence in respect of screening is concerned. No single method exists with both, high sensitivity and high specificity for screening purpose. Data are also not sufficient to recommend combinations of methods. Only two economic models on cost-effectivenes of screening investigations could be identified. No economic evaluations of the most recent methods can be found in the published literature. A British cost-effectiveness analysis calculates cost per true positives and favours a combination of ophthalmoscopy, tonometry and perimetry either for people at high risk for glaucoma or for the total population as an initial examination. A Canadian HTA-report models the cost per year of blindness avoided. The report concludes that because of a high degree of uncertainty with respect to the benefits and the high costs involved, the setting-up of a glaucoma-screening program cannot be supported. </Pgraph>
      <SubHeadline2>Discussion</SubHeadline2>
      <Pgraph>The literature shows that combinations of methods have to be used for screening of glaucoma in order to get reasonable values of sensitivity and specificity. Presently no combination of methods and no algorithm can be presented for glaucoma screening with sufficient evidence. Also no conclusions about cost-effectiveness for Germany can be made based on the available literature. </Pgraph>
      <SubHeadline2>Conclusions</SubHeadline2>
      <Pgraph>In order to find the optimal combination of methods for glaucoma-screening, population-based studies have to be performed. Therefore also no final conclusions can be drawn with respect to cost-effectiveness of glaucoma-screening methods. The economic evaluation of a clinical effective screening-method should consider the effects of blindness avoided, as well as effects on the prevention of visual impairment.</Pgraph>
    </Abstract>
    <TextBlock linked="yes" name="Executive Summary">
      <MainHeadline>Executive Summary</MainHeadline>
      <SubHeadline>1. Health political background</SubHeadline>
      <Pgraph>Glaucoma is a progressive disease of the eye, which may lead to visual impairment or blindness if undiagnosed and untreated. About 950,000 people are affected by primary open angle glaucoma (POAG) in Germany, an estimated 50&#37; of which are undiagnosed. Glaucoma is the third commonest cause of blindness in industrialised nations. In Germany about 16,500 persons are registered blind in both eyes due to glaucoma and receive blindness allowance. According to other sources an estimated 50,000 persons are blind due to glaucoma. The German Opthalmological Society (DOG) and the German Association of Ophthalmologists (BVA) recommend a screening for glaucoma according to their guidelines for all persons between the ages of 40 to 64 in a triennial interval and for persons over the age of 65 in annual to biannual intervals. The Federal Joint Committee (G-BA) disapproved the introduction of a glaucoma-screening program on expense of the compulsory health insurance in December 2004 because of insufficient valid data on test procedures and combinations of tests, age limits and screening-intervals as well as insufficient data on early treatment of glaucoma on the criteria &#8220;prevention of blindness&#8221;. Currently charges of examinations for early detection of glaucoma are only borne by compulsory health insurance in case of suspected early symptoms or if certain risk factors are prevalent. Otherwise the costs of about 16 to 20 EURO of an examination for glaucoma (including Anamnesis, ophthalmoscopy and tonometry) have to be borne by the patient.</Pgraph>
      <SubHeadline>2. Scientific background</SubHeadline>
      <Pgraph>Glaucoma is a group of optic neuropathies that have in common a degeneration of retinal ganglion cells and their axons. POWG is the most common form. Increased ocular pressure is today recognised as one of several risk factors. It is found independent of glaucoma as &#8220;ocular hypertension&#8221;. On the other hand, glaucoma can be diagnosed independent of increased ocular pressure, which is termed &#8220;normal tension glaucoma&#8221;.</Pgraph>
      <Pgraph>The diagnosis of Glaucoma is based on the evaluation of the optic disc, retinal fibre layer and visual field. Morphological changes of the optic disc and retinal fibre layer are analysed by ophthalmoscopic evaluation (including fundus photography and nerve fibre layer photography), the confocal scanning laser tomography (usually with the Heidelberg Retinatomograph), the scanning laser polarimetry (GDx), the retinal thickness analysis and optical coherence tomography. Scotomas are diagnosed by perimetry. In addition to the standard automated perimetry, methods such as frequency doubling perimetry (FDT) and short wavelength automated perimetry can detect glaucoma earlier. Intraocular pressure, the most important treatable risk factor, can be measured by tonometry.</Pgraph>
      <Pgraph>Clinical signs of glaucoma are subtle, the disease progression is slowly progredient and already existing visual loss can not be reversed. Therefore, early diagnosis and screening are essential components from a medical point of view.</Pgraph>
      <SubHeadline>3. Research questions</SubHeadline>
      <Pgraph>Following research questions are posed: What is the diagnostic validity of screening-tests for POAG, as well as for two other forms (pigmentary glaucoma and pseudoexfoliation glaucoma, which are related to POAG concerning diagnosis and therapy)&#63; Which risks are associated with these screening-tests&#63; Are screening-tests for POAG cost-effective&#63; Which ethical and legal issues are associated with a screening for POAG&#63; The questions are posed with respect to the use in a screening setting in Germany. </Pgraph>
      <SubHeadline>4. Methods</SubHeadline>
      <Pgraph>This HTA-report follows the method of a systematic review. Out of 2602 abstracts yielded by a systematic literature research in 35 international databases (DIMDI HTA-Superbase and Cochran-Databases, October 2005) 55 studies were included for medical assessment, three publications were included for the economic assessment (one double count with medical literature) and two articles remained for the ethical discussion after a two-stage selection process according to predefined criteria. For the discussion of legal aspects relevant juridical texts were included. </Pgraph>
      <SubHeadline>5. Results</SubHeadline>
      <Pgraph>Out of 55 medical articles related to the research question, eight primary studies investigate only perimetric methods, nine confocal scanning laser ophthalmoscopy and eight scanning laser polarimetry. One of these methods is being investigated in combination with other methods in 13 primary studies and eleven articles analyse several other methods. Six systematic reviews or HTA-Reports were used. The majority of studies is based on patients investigated at universities and therefore the quality of the papers is generally low, as far as the evidence in respect of screening is concerned. However, also studies performed under screening conditions have methodical limitations.</Pgraph>
      <Pgraph>Out of eight articles investigating perimetry by FDT only or in combination with other perimetric methods, only one study was performed as a public screening. In this study FDT has a sensitivity of 92&#37; and a specificity of 93&#37;. Another study uses a non-mydriatic fundus camera in combination with FDT for screening in a general population. The sensitivity for FDT in relation to the camera is 58.6&#37; and the specificity is 64.3&#37;. The screening study with the best quality finds sensitivities between 78.9&#37; and 84.2&#37; and specificities between 55.0&#37; and 65.7&#37; depending on the threshold used. Studies investigating clinical populations show sensitivities between 29&#37; and 100&#37; and specificities between 81&#37; and 100&#37;.</Pgraph>
      <Pgraph>No study could be found evaluating only scanning laser tomography in a screening setting. In the available studies with clinical populations sensitivities for the HRT are between 26.5&#37; in preperimetric and 97&#37; in perimetric glaucoma patients. Specificities lie between 65&#37; and 95&#37;. The above mentioned screening study (including also FDT) with the best quality shows sensitivities between 89.5&#37; and 94.7&#37; and specificities between 80.6&#37; and 90.5&#37; for the HRT depending on the threshold used. </Pgraph>
      <Pgraph>There are only two studies evaluating scanning laser polarimetry under screening conditions. In a study with medium quality using a modulation parameter the optimal sensitivity is 86&#37; and the specificity is 90&#37;. The second study is of lower quality and only a sensitivity of 82&#37; is reported. Studies investigating clinical populations have sensitivities between 62&#37; and 100&#37; and specificities between 73&#37; and 100&#37;.</Pgraph>
      <Pgraph>No single method exists with both, high sensitivity and high specificity for screening purpose. The results of all studies investigating several methods show uniformly that sensitivity, specificity and receiver operating characteristic (ROC) curves (showing sensitivity and specificity graphically) can be improved by combining methods and using adequate algorithms. This is also true for others than the reported methods.</Pgraph>
      <Pgraph>The advantage of a sequential diagnostic is confirmed by a qualitatively high Australian screening study. Using simple methods (visual acuity, family history of glaucoma, FDT) in a first stage reduces the number of participants by 59.3&#37;. The second stage (scanning laser tomography) is only performed when results of the first stage are pathological. The optimal screening strategy combing visual acuity, family history of glaucoma, FDT and HRT has 96.8&#37; and 89.7&#37; sensitivity and specificity, respectively.</Pgraph>
      <Pgraph>Systematic reviews and HTA-reports do not give evidence based recommendations for screening of glaucoma. A Canadian HTA-report concludes that the evidence is not sufficient in order to recommend or reject a general screening for ocular hypertension or POAG. Regarding the risk of the examinations, only eye drops or methods having direct contact with the cornea comprise a small risk for adverse events.</Pgraph>
      <Pgraph>Out of seven publications relevant for the economic assessment, two economic models (three publications) on cost-effectiveness of screening-tests could be identified, which have a good quality.</Pgraph>
      <Pgraph>A British cost-effectiveness analysis published in 1997 calculates cost per true positive for various combinations of the three main tests ophthalmoscopy, perimetry and tonometry and associated referral criteria in a primary care setting. The study assumes a prevalence of 0.6&#37; of previously undetected glaucoma in the screening-population and calculates one screening-cycle. The combination of ophthalmoscopy and tonometry for all persons <TextGroup><PlainText>screened</PlainText></TextGroup> and perimetry as an initial test only for persons at high risk (or for all persons) shows at a sensitivity of 80&#37; (87&#37;) a cost-effectiveness ratio of 1745 USD (2057 USD) per true positive diagnosis, including all direct costs of diagnosis. Both above mentioned screening-modes show a specificity of &#8805;97&#37;. A screening is most economic, if it is conducted as a part of a general eye examination (&#8220;case-finding&#8221;) thus the cost of the ophthalmoscopy and overhead-cost could be minimized. Furthermore costs could be reduced if tonometry (non-contact tonometry) and &#47; or perimetry would be performed by non-ophthalmologically trained assistants.</Pgraph>
      <Pgraph>A Canadian HTA-report published in 1995 models the cost per year of blindness avoided, thus considering costs of diagnosis and treatment as well as benefits from blindness avoided. In 14 scenarios different combinations of screening-examinations (primarily funduscopy and tonometry as an initial examination and perimetry as a secondary test), screening-intervals, age-limits and rates of participation, compliance and effectiveness of treatment are considered. From a government perspective (Quebec) a screening of persons aged 40 to 79 in an interval of three (five) years, with an assumed participation and compliance rate of 75&#37; each and an assumed effectiveness of treatment of 50&#37;, could avoid 354 years of blindness, which corresponds to a cost-effectiveness ratio of 100,000 CAD (78,000 CAD) per year of blindness <TextGroup><PlainText>avoided</PlainText></TextGroup>. Years in partial blindness, which might be prevented by a glaucoma screening and subsequent treatment, are not considered in the outcome-parameter. The authors of the Canadian HTA report conclude that <TextGroup><PlainText>because</PlainText></TextGroup> of a high degree of uncertainty with respect to benefits and the high costs involved, the setting-up of a glaucoma-screening program cannot be supported. </Pgraph>
      <Pgraph>No economic evaluations of the most recent methods (as described in the medical assessment of this HTA) can be found in the published literature.</Pgraph>
      <Pgraph>Two cost-analysis of screening-programmes in different settings (a low cost screening conducted by non-medical students and a screening conducted in the out-patient department of a university hospital) do not describe transparently all costs incorporated in the analysis, furthermore they are only of minor relevance because of the specific setting used.</Pgraph>
      <Pgraph>Only two articles considering ethical aspects of a screening for POAG could be identified by the literature search. No further relevant publications could be identified by hand search. </Pgraph>
      <Pgraph>Both articles discuss the benefits of glaucoma screening and treatment on a general basis. Amongst other it is discussed that there are no studies with clear endpoints (blindness) for the appraisal of glaucoma screenings. According to WHO criteria it is necessary for a screening that such studies exist.</Pgraph>
      <Pgraph>From a juristic point of view it is important, that some medical examinations which are relevant for the detection of glaucoma (like the tonometry) are only reimbursed if certain risk factors or definite suspicious findings exist. However, there is a wide scope in the interpretation of this risk factors.</Pgraph>
      <SubHeadline>6. Discussion</SubHeadline>
      <Pgraph>For the detection of POAG (as well as pigmentary glaucoma and pseudoexfoliation glaucoma, which are related to POAG concerning diagnosis and therapy) several methods of investigation can be used. However, the evaluated literature shows that no single method, but also no combination of methods is presently established for screening of glaucoma. The number and quality of the studies is presently not sufficient to allow the recommendation of a method or a combination of methods. Studies on early diagnosis and screening of glaucoma include most commonly FDT as a perimetric method and confocal scanning laser tomography and scanning laser polarimetry as morphologic methods. The establishment of morphologic methods for glaucoma screening can be more elaborative because morphologic changes can occur at an early stage, at which part of the standard diagnosis (standard perimetry) can still be normal. Therefore longitudinal studies have to be performed in order to confirm that early morphologic changes are related to glaucomatous visual field defects at a later stage.</Pgraph>
      <Pgraph>One of the few population based studies with sufficient quality has good results regarding sensitivity and specificity using simple methods such as visual acuity and family history of glaucoma. Such parameters are rarely investigated in the available studies but could also be used in screening programs, as well as an ophthalmologic examination and tonometry. An essential part of the above mentioned screening study is the sequential course with simple methods at a first stage and more complex methods at a second stage.</Pgraph>
      <Pgraph>From an economic perspective no recommendation for a single screening test or combination of screening test can be given. Currently no economic evaluations of the more recent methods such as FDT or scanning-laser-polarimetry are published. Economic Evaluations assessed consider ophthamalmoscopy, perimetry and tonometry or combinations of these in the context of the British and the Canadian Health system; an adaptation of the results to the German health care system has to be critically assessed. </Pgraph>
      <Pgraph>A screening-pathway, as recommended by the BVA and DOG in their Guideline 15c on the detection of glaucoma, shows a lower sensitivity at higher cost per true-positive diagnoses from the perspective of the British National Health Service, than a screening mode including perimetry for patients at risk in the initial examination. The Canadian evaluation calculates cost per year of blindness avoided; the study authors conclude that because of the high degree of uncertainty and because of the high cost no support for a formal glaucoma screening program can be <TextGroup><PlainText>given</PlainText></TextGroup>.</Pgraph>
      <Pgraph>With respect to a comparison of screening-tests or combination of these the intermediate parameter cost per true-positive diagnosis is appropriate. An economic evaluation of a glaucoma-screening, aiming at morbidity-related outcome-parameters, should not only consider the effects on blindness, but also on visual impairment. </Pgraph>
      <Pgraph>From current projects assessing (the medical and) economic effectiveness of screening for glaucoma (e. g. by the &#8220;National Coordinating Centre for Health Technology Assessment&#8221; (NCCHTA)) evaluations of more recent screening-test might be expected. </Pgraph>
      <Pgraph>From an ethical and juristic point of view the unclear situation concerning reimbursement of medical examinations which are relevant for the detection of glaucoma (like a tonometry) could be a problem especially for poorer classes of population. The decision if such a medical examination is reimbursed by the GKV or not, depends highly on the argumentation to the GKV of the doctor or the patient.</Pgraph>
      <SubHeadline>7. Conclusions&#47;recommendations</SubHeadline>
      <Pgraph>Presently neither a single nor a combination of methods can be recommended with sufficient evidence for the detection of POAG. The diagnostic validity of single methods is not high enough. A useful combination would be a functional test (such as FDT) together with a morphologic method (such as an ophtlamologic ecxamination, confocal scanning laser tomography or scanning laser polarimetry). Tonometry has been used earlier, but can not be used solely because of its poor sensitivity. <TextGroup><PlainText>However,</PlainText></TextGroup> it could be a useful part of a screening algorithm because of its high specificity. Simple methods such as visual acuity and family history of glaucoma could also be part of such programs.</Pgraph>
      <Pgraph>Future studies have to evaluate the optimal combination and order of methods. High sensitivity and specificity are not the only relevant parameters for establishing screening programs. An improved management of patients is also essential, which can only be reached by randomised controlled intervention studies with visual parameters as end points.</Pgraph>
      <Pgraph>No final conclusions can be drawn with respect to cost-effectiveness of glaucoma-screening methods from the published literature or by adapting the results of published economic evaluations to the German context. An economic evaluation of a screening-programme should consider the fact, that by screening for glaucoma other eye diseases could be detected early, which might yield medical and economic benefits. Furthermore an economic evaluation of a clinically effective screening-method should consider the effects of blindness avoided, as well as effects on the prevention of visual impairment.</Pgraph>
    </TextBlock>
    <TextBlock linked="yes" name="Kurzfassung">
      <MainHeadline>Kurzfassung</MainHeadline>
      <SubHeadline>1. Gesundheitspolitischer Hintergrund</SubHeadline>
      <Pgraph>Das Glaukom (umgangssprachliche Bezeichnung: gr&#252;ner Star) ist eine progressiv verlaufende Augenerkrankung, die unentdeckt bzw. unbehandelt zu einer eingeschr&#228;nkten Sehleistung bis hin zur Erblindung f&#252;hren kann. Es wird gesch&#228;tzt, dass bei rund 950.000 Personen in Deutschland ein prim&#228;res Offenwinkelglaukom (POWG) vorliegt und weniger als 50&#37; der POWG den Betroffenen in Industriel&#228;ndern bekannt sind. Glaukome stellen die dritth&#228;ufigste Erblindungsursache in Industrienationen dar; in Deutschland sind ca. 16.500 Menschen beidseitig in Folge eines Glaukoms erblindet und beziehen deshalb Blindengeld, andere Quellen berichten von bis zu 50.000 auf Grund eines Glaukoms erblindeten Personen. Der Berufsverband der Augen&#228;rzte Deutschlands e. V. (BVA) und die Deutsche Ophthalmologische Gesellschaft (DOG) empfehlen ein Glaukomscreening gem&#228;&#223; ihrer Leitlinie Nr. 15 c allen Personen zwischen 40 und 64 Jahren im Intervall von drei Jahren, sowie f&#252;r Personen &#252;ber 65 Jahren in Abst&#228;nden von ein bis zwei Jahren. Der gemeinsame Bundesausschuss (G-BA) hat mit Beschluss vom 21. Dezember 2004 eine Einf&#252;hrung eines Glaukomscreenings zu Lasten der gesetzlichen Krankenversicherung (GKV) auf Grund der unzureichenden Datenlage zu den Testverfahren, Altersgrenzen und Screeningintervallen sowie den unzureichenden Informationen der Auswirkung einer fr&#252;hzeitigen Behandlung von Glaukompatienten auf das Zielkriterium Erblindung, abgelehnt. Die Kosten f&#252;r eine Glaukom-Fr&#252;herkennungsuntersuchung werden nicht generell, sondern nur bei konkreten Verdachtsmomenten f&#252;r das Bestehen eines Glaukoms bzw. Vorliegen bestimmter Risikofaktoren f&#252;r das Auftreten eines Glaukoms von den gesetzlichen Krankenversicherungen &#252;bernommen. Die Glaukom-Fr&#252;herkennungsuntersuchung (Sehnervcheck: Anamnese, allgemeine augen&#228;rztliche Untersuchung, Tonometrie) kann von Patienten als individuelle Gesundheitsleistung (IGeL) in Anspruch genommen werden, der Patient hat die Kosten von etwa 16 bis 20 EURO f&#252;r die Untersuchung selbst zu tragen.</Pgraph>
      <SubHeadline>2. Wissenschaftlicher Hintergrund</SubHeadline>
      <Pgraph>Unter dem Begriff Glaukom werden Augenerkrankungen zusammengefasst, die durch Sch&#228;digungen des Sehnervkopfs, seiner Nervenfasern und der Netzhaut gekennzeichnet sind. Die h&#228;ufigste Glaukomart ist das POWG. Ein erh&#246;hter Augeninnendruck (intraokul&#228;rer Druck &#61; IOD) gilt heute nur als einer von mehreren Risikofaktoren. Er kann auch isoliert vorkommen, ohne dass Anzeichen f&#252;r ein Glaukom zu finden sind und wird als okul&#228;re Hypertension (OHT) bezeichnet. Andererseits kann die Diagnose Glaukom gestellt werden, ohne dass ein erh&#246;hter IOD besteht (Normaldruckglaukom).</Pgraph>
      <Pgraph>Die Diagnostik des Glaukoms beruht in erster Linie auf der Beurteilung der Papille (Sehnervkopf), der Nervenfasern der Netzhaut (retinale Nervenfasern) und der Gesichtsfeldausf&#228;lle. Bei Papillen- und Nervenfasernuntersuchungen werden strukturelle Sch&#228;den analysiert, w&#228;hrend die Untersuchung des Gesichtsfelds funktionelle Defekte beschreibt. Zu den wichtigsten Papillen- und Nervenfasernuntersuchungen z&#228;hlen die ophthalmoskopische Untersuchung, wobei eine fotografische Dokumentation mittels Papillenfotografie bzw. Nervenfasernfotografie m&#246;glich ist, die konfokale Scanning-Laser-Tomographie (das am h&#228;ufigsten verwendetet Ger&#228;t ist der Heidelberger Retinatomograph (HRT), die Scanning-Laser-Polarimetrie (mit dem GDx-Ger&#228;t), die Untersuchung mit dem &#8222;Retinal Thickness Analyzer&#8220; (RTA) und die optische Koh&#228;renztomographie (OCT). Untersuchungen zur Erfassung von Gesichtsfeldausf&#228;llen werden als perimetrische Methoden bezeichnet. Neben der Standardperimetrie gibt es auch Methoden, die glaukomat&#246;se Gesichtsfeldausf&#228;lle fr&#252;her erkennen, wie den Frequenzverdopplungstest und die Blau-Gelb-Perimetrie. Die Messung des wichtigsten therapierbaren Risikofaktors, des IOD, erfolgt mittels Tonometrie.</Pgraph>
      <Pgraph>Da die Erkrankung vom Patienten erst mit Auftreten funktioneller Sch&#228;digungen bemerkt wird, bestehende Sch&#228;den aber nicht mehr r&#252;ckg&#228;ngig gemacht werden k&#246;nnen, kommt der Fr&#252;herkennung des Glaukoms aus medizinischer Sicht eine wesentliche Bedeutung zu.</Pgraph>
      <SubHeadline>3. Forschungsfragen</SubHeadline>
      <Pgraph>Der Bericht geht folgenden Fragestellungen nach: Welche medizinische Erkennungsg&#252;te weisen Screeninguntersuchungen zur Entdeckung eines POWG bzw. diesem in der Diagnostik nahe stehenden Glaukomen (Pigmentglaukom und Pseudoexfoliationsglaukom (PEX)) auf&#63; Welche Risiken bergen sie&#63; Wie stellt sich die Kosteneffektivit&#228;t von Screeninguntersuchungen zur Entdeckung eines POWG dar&#63; Welche ethischen und juristischen Implikationen sind damit verbunden&#63; </Pgraph>
      <SubHeadline>4. Methodik</SubHeadline>
      <Pgraph>Vorliegender HTA-Bericht verfolgt die Methodik eines systematischen Literaturreviews. Von den 2602 aus der systematischen Literatursuche (DIMDI HTA-Superbase sowie in HTA- und Cochrane-Datenbanken, Oktober 2005) resultierenden Abstracts, verbleiben nach einem zweiteiligen Selektionsprozess nach einheitlichen, vorab definierten Kriterien 55 Volltexte f&#252;r die Beantwortung der medizinischen Fragestellung, drei Texte werden f&#252;r die &#246;konomische Fragestellung bewertet (eine Doppelz&#228;hlung zu Medizin), zwei Artikel werden der Behandlung der ethischen Aspekte zugeordnet. F&#252;r die Behandlung der juristischen Aspekte werden relevante Gesetzestexte herangezogen. </Pgraph>
      <SubHeadline>5. Ergebnisse</SubHeadline>
      <Pgraph>Von insgesamt 55 Volltexten, die f&#252;r die medizinische Themenstellung im weiteren Sinn von inhaltlicher Relevanz sind, untersuchen acht Prim&#228;rstudien ausschlie&#223;lich perimetrische Untersuchungsmethoden, neun die Scanning-Laser-Tomographie und acht die Scanning-Laser-Polarimetrie. Bei 13 Prim&#228;rstudien wird zumindest eine der angef&#252;hrten Methoden in Kombination mit anderen Methoden verwendet und elf Arbeiten untersuchen diverse andere Untersuchungstechniken. Au&#223;erdem stehen sechs &#220;bersichtsarbeiten bzw. HTA-Berichte zur Verf&#252;gung. Zur Qualit&#228;t der Prim&#228;rstudien ist zu sagen, dass nur wenige Arbeiten unter Screeningbedingungen durchgef&#252;hrt werden. Die gro&#223;e Mehrzahl an Arbeiten untersucht - oft an universit&#228;ren Einrichtungen - ein klinisches Patientenkollektiv, weshalb die Studienqualit&#228;t bez&#252;glich der Verwertbarkeit auf Screeningverh&#228;ltnisse als niedrig eingestuft werden muss. Allerdings zeigen auch die unter Screeningbedingungen durchgef&#252;hrten Studien qualitative M&#228;ngel.</Pgraph>
      <Pgraph>Von acht Arbeiten, die die Perimetrie mit Frequenzverdopplungstechnik (FDT) isoliert bzw. in Kombination mit anderen perimetrischen Methoden untersuchen, werden die untersuchten Probanden nur in einer Studie anhand eines &#246;ffentlichen Screenings rekrutiert. Bei dieser Arbeit liegt die Sensitivit&#228;t der FDT bei 92&#37; und die Spezifit&#228;t bei 93&#37;. Eine weitere unter Screeningbedingungen durchgef&#252;hrte Studie verwendet neben der FDT eine nicht-mydriatische Funduskamera. Bezogen auf die Befunde der Funduskamera erreicht die FDT nur eine Sensitivit&#228;t von 58,6&#37; und eine Spezifit&#228;t von 64,3&#37;. Die qualitativ beste Screeningstudie findet f&#252;r die FDT je nach verwendetem Grenzwert eine Sensitivit&#228;t zwischen 78,9&#37; und 84,2&#37; und eine Spezifit&#228;t zwischen 55,0&#37; und 65,7&#37;. Arbeiten an klinischen Kollektiven mit entsprechend geringer Evidenz f&#252;r Screeningverh&#228;ltnisse erreichen Sensitivit&#228;tswerte zwischen 29&#37; und 100&#37; und Spezifit&#228;tswerte zwischen 81&#37; und 100&#37;. </Pgraph>
      <Pgraph>Keine einzige Arbeit untersucht die Scanning-Laser-Tomographie isoliert unter Screeningbedingungen. Bei den vorliegenden Arbeiten mit klinischen Kollektiven werden mit dem HRT Sensitivit&#228;tswerte zwischen 26,5&#37; bei pr&#228;perimetrischen und 97&#37; bei perimetrischen Glaukomen gefunden. Die Spezifit&#228;t liegt zwischen 65&#37; und 95&#37;. Die oben erw&#228;hnte qualitativ hoch stehende Screeningstudie, die auch die FDT einsetzt, zeigt beim HRT je nach verwendetem Grenzwert eine Sensitivit&#228;t zwischen 89,5&#37; und 94,7&#37; und eine Spezifit&#228;t zwischen 80,6&#37; und 90,5&#37;.</Pgraph>
      <Pgraph>Es liegen insgesamt nur zwei Arbeiten vor, die die Scanning-Laser-Polarimetrie unter Screeningbedingungen testen. Bei einer Studie mit mittlerer Qualit&#228;t betr&#228;gt unter Verwendung eines Modulationsparameters die optimale Sensitivit&#228;t 86&#37; und die Spezifit&#228;t 90&#37;. Die zweite Studie ist von niedriger Qualit&#228;t und gibt nur eine Sensitivit&#228;t von 82&#37; an. Bei Arbeiten an klinischen Kollektiven liegt die Sensitivit&#228;t zwischen 62&#37; und 100&#37; und die Spezifit&#228;t zwischen 73&#37; und 100&#37;.</Pgraph>
      <Pgraph>Bei keiner einzigen Methodik sind die Daten ausreichend gut, um sie isoliert zum Glaukomscreening verwenden zu k&#246;nnen. Die Ergebnisse aller Arbeiten, die mehrere Methoden untersuchen, zeigen einheitlich, dass Sensitivit&#228;t, Spezifit&#228;t und &#8222;Receiver Operating Characteristic Curves&#8220; (ROC-Kurven: graphische Darstellung von Sensitivit&#228;t und Spezifit&#228;t) durch Kombination von Untersuchungsmethoden und Verwendung entsprechender Algorithmen verbessert werden. Dies gilt auch f&#252;r andere als die bisher beschriebenen Untersuchungsmethoden.</Pgraph>
      <Pgraph>Der Vorteil einer sequentiellen Diagnostik wird in einer qualitativ hoch stehenden australischen Screeninguntersuchung best&#228;tigt, bei der durch die Anwendung einfacher Untersuchungsmethoden (Sehsch&#228;rfenbestimmung, Familienanamnese f&#252;r Glaukom und FDT) in einem ersten Schritt die Teilnehmeranzahl um 59,3&#37; reduziert wird. Der zweite Untersuchungsschritt (Scanning-Laser-Tomographie) wird erst bei Vorliegen auff&#228;lliger Befunde der ersten Untersuchungsstufe durchgef&#252;hrt. Die bez&#252;glich der Grenzwerte optimierte Kombination von Sehsch&#228;rfenbestimmung, Familienanamnese, FDT und HRT erbringt insgesamt gute Ergebnisse mit einer Sensitivit&#228;t von 96,8&#37; und einer Spezifit&#228;t von 89,7&#37;.</Pgraph>
      <Pgraph>In systematischen &#220;bersichtsarbeiten und HTA-Berichten sind keine evidenzbasierten Empfehlungen f&#252;r bestimmte Untersuchungsmethoden zum Glaukomscreening zu finden. Ein &#228;lterer kanadischer und ein aktueller US-amerikanischer HTA-Bericht stufen die Evidenzlage als unzureichend ein, um ein allgemeines Screening auf OHT und POWG zu bef&#252;rworten oder abzulehnen. Zum Risiko der in Frage kommenden Untersuchungsverfahren ist zu sagen, dass lediglich bei Augentropfen und bei Ger&#228;ten, die einen direkten Kontakt mit der Hornhaut erfordern, ein geringes Risiko f&#252;r unerw&#252;nschte Nebenwirkungen besteht.</Pgraph>
      <Pgraph>Von sieben f&#252;r die &#246;konomische Fragestellung relevanten Publikationen ermitteln zwei Modellrechnungen (drei Publikationen) Kosteneffektivit&#228;tsverh&#228;ltnisse f&#252;r verschiedene Screeningprogramme, wobei die Qualit&#228;t der Arbeiten als gut einzustufen ist. </Pgraph>
      <Pgraph>Eine britische Modellrechnung von 1997 ermittelt die Kosten je richtig-positive Diagnose verschiedener Screeningpfade (Kombinationen von Ophthalmoskopie, Tonometrie und Perimetrie unter Annahme unterschiedlicher Schwellenwerte als &#220;berweisungskriterien) auf Ebene der prim&#228;ren Gesundheitsversorgung. Die Studie bezieht sich auf einen Screeningzyklus bei einer Pr&#228;valenz von 0,6&#37; unentdeckten Glaukomen in der Bev&#246;lkerung &#252;ber 40 Jahren. Der Screeningpfad Ophthalmoskopie und Tonometrie sowie Perimetrie f&#252;r alle Personen (bzw. Personen mit hohem Glaukomrisiko) als Erstuntersuchung unter Ber&#252;cksichtigung definierter &#220;berweisungskriterien weist bei einer Sensitivit&#228;t von 87&#37; (80&#37;) ein Kosteneffektivit&#228;tsverh&#228;ltnis von 2057 USD (1745 USD) je richtig-positive Diagnose unter Ber&#252;cksichtigung aller direkten medizinischen Kosten auf. Beide Untersuchungsmodi weisen eine Spezifit&#228;t von &#8805;97&#37; auf. Ein Screening stellt sich in der Modellrechnung am wirtschaftlichsten dar, wenn es im Rahmen von anders motivierten Augenuntersuchungen durchgef&#252;hrt wird und damit die Kosten der Ophthalmoskopie sowie die &#8222;Overhead&#8220;-Kosten minimiert werden und nicht-&#228;rztliches Personal eingebunden wird (Non-Kontakttonometrie, moderne Perimeter).</Pgraph>
      <Pgraph>Ein kanadischer HTA-Bericht von 1995 stellt die Kosten der Untersuchungen verschiedener Screeningpfade und der nachfolgenden Behandlung dem Ergebnisparameter vermiedene Jahre Blindheit gegen&#252;ber. In 14 Szenarien werden unterschiedliche Kombinationen von Untersuchungen (im Wesentlichen als Erstuntersuchung Fundusuntersuchung und Tonometrie, Perimetrie erst im zweiten Untersuchungsgang), Variationen der Screeningintervalle, der Altersgruppe und der Annahmen &#252;ber Partizipation am Screening, Compliance bei der Behandlung und Effektivit&#228;t der Behandlung betrachtet. Aus Perspektive der &#246;ffentlichen Verwaltung (Ministerium f&#252;r Gesundheit und Soziales) k&#246;nnen mit einem Screening der 40- bis <TextGroup><PlainText>79-J&#228;hrigen</PlainText></TextGroup> im Intervall von drei (f&#252;nf) Jahren bei je 75&#37; Partizipation und Compliance sowie 50&#37; Effektivit&#228;t der Therapie, 354 Jahre in Blindheit vermieden werden, was einem Kosteneffektivit&#228;tsverh&#228;ltnis von 100.000 CAD (78.000 CAD) pro vermiedenes Jahr Blindheit entspricht. Im Ergebnisparameter ist der gesundheitsbezogene Nutzen aus Jahren vermiedener Sehbehinderung nicht ber&#252;cksichtigt. Die Studienautoren sprechen sich auf Grund der unsicheren Datenlage und der hohen Kosten gegen die Durchf&#252;hrung eines Glaukomscreenings in Quebec aus. </Pgraph>
      <Pgraph>Modellrechnungen zu neueren Untersuchungsmethoden wie in der medizinischen Bewertung beschrieben (siehe oben) konnten nicht identifiziert werden. </Pgraph>
      <Pgraph>Zwei Kostenauswertungen zu Screeningprogrammen in unterschiedlichem Setting (Billigscreeningstrategie von nicht-medizinischem Personal (Studenten) durchgef&#252;hrt und Screening in der Ambulanz eines Universit&#228;tskrankenhauses) erf&#252;llen nicht alle Kriterien der transparenten Darstellung der Eingangsparameter und weisen auf Grund des Settings nur bedingt Relevanz auf.</Pgraph>
      <Pgraph>Nur zwei Artikel, die die f&#252;r den Bericht relevanten ethischen Aspekte (allerdings auch nur am Rand) behandeln, konnten identifiziert werden. Die Handsuche ergab keine zus&#228;tzlichen relevanten Publikationen. </Pgraph>
      <Pgraph>Die beiden Artikel zur ethischen Betrachtung setzen sich allgemein mit dem Nutzen von Screening- und Therapiema&#223;nahmen bei Glaukomerkrankungen auseinander. Unter anderem setzen sich die beiden Studien damit auseinander, dass f&#252;r die Bewertung eines Glaukomscreenings Studien zur Effektivit&#228;t der Therapie mit klaren Endpunkten (Erblindung) fehlen. Das Vorhandensein solcher Studien z&#228;hlt allerdings zu den Voraussetzungen f&#252;r ein Screening nach den WHO-Kriterien.</Pgraph>
      <Pgraph>In Bezug auf juristische Aspekte ist relevant, dass bei konkreten Verdachtsmomenten bzw. bestimmten Risikofaktoren (siehe oben) die im Leistungskatalog der gesetzlichen Krankenkasse eingeschlossenen augen&#228;rztlichen Untersuchungen erstattet werden, wobei dem Leistungsanbieter bei der Interpretation der Kriterien ein Ermessensspielraum zukommt. </Pgraph>
      <SubHeadline>6. Diskussion</SubHeadline>
      <Pgraph>Zur Erfassung von POWG bzw. diesen in der Diagnostik nahe stehenden Glaukomen (Pigmentglaukom und PEX) kommen prinzipiell mehrere Untersuchungsmethoden in Frage. Die bewerteten Arbeiten zeigen jedoch, dass derzeit keine einzelne Untersuchungsmethodik, aber auch keine Kombination von Methoden f&#252;r ein effektives Glaukomscreening in der Praxis etabliert ist. Es liegen noch zu wenige qualitativ hoch stehende Screeninguntersuchungen vor, die mit gen&#252;gend hoher Evidenz den effektiven Einsatz bestimmter Untersuchungsmethoden oder einer Kombination von Untersuchungsmethoden zur Entdeckung dieser Glaukomarten belegen. Arbeiten, die sich mit Fr&#252;hdiagnostik und Screening besch&#228;ftigen, untersuchen von den perimetrischen Methoden am h&#228;ufigsten die FDT und unter den morphologischen Methoden am h&#228;ufigsten die Scanning-Laser-Polarimetrie und die Scanning-Laser-Tomographie. Die Etablierung morphologischer Methoden als Untersuchungsmethode f&#252;r das Screening etwas aufw&#228;ndiger, weil morphologische glaukomat&#246;se Ver&#228;nderungen bereits zu einem Zeitpunkt auftreten k&#246;nnen, zu dem bei einem wesentlichen Teil der Standarddiagnose (der Standardperimetrie) noch keine Auff&#228;lligkeiten auftreten m&#252;ssen. Die Eignung zum Screening in der Praxis kann daher nur anhand von Longitudinalstudien belegt werden, bei denen pathologische morphologische Ver&#228;nderungen mit zeitlicher Verz&#246;gerung auch von entsprechenden Gesichtsfelddefekten begleitet sind. </Pgraph>
      <Pgraph>Eine der wenigen populationsbasierten Screeningstudien mit zufriedenstellender Qualit&#228;t zeigt gute Ergebnisse bez&#252;glich Sensitivit&#228;t und Spezifit&#228;t unter Verwendung einfacher Methoden wie Sehsch&#228;rfenbestimmung und Erhebung der Familienanamnese. Diese werden im Rahmen der bewerteten Studien kaum untersucht, kommen aber f&#252;r Screeningprogramme ebenfalls in Frage, wie auch eine augenfach&#228;rztliche Untersuchung und die Tonometrie. Wesentliches Element dieser Screeningstudie ist das sequentielle Vorgehen, wobei zun&#228;chst einfache und erst in einem zweiten Schritt aufw&#228;ndigere Methoden eingesetzt werden. </Pgraph>
      <Pgraph>Aus &#246;konomischer Sicht kann derzeit keine eindeutige Empfehlung f&#252;r ein einzelnes Verfahren oder eine Kombination von Screeninguntersuchungen gegeben werden. F&#252;r die neueren Untersuchungsverfahren wie die FDT oder die Scanning-Laser-Polarimetrie liegen noch keine &#246;konomischen Bewertungen vor. Die bewerteten Studien untersuchen herk&#246;mmliche Verfahren bzw. Kombinationen dieser und wurden im Kontext des britischen bzw. kanadischen Gesundheitssystems erstellt. Eine &#220;bertragung der Ergebnisse ist unter Ber&#252;cksichtigung des deutschen Entscheidungskontexts kritisch zu pr&#252;fen. </Pgraph>
      <Pgraph>Ein Screeningpfad, wie von der BVA und DOG in ihrer Leitlinie 15c empfohlen, weist in der britischen Modellrechnung eine geringere Sensitivit&#228;t bei (aus Sicht des nationalen Gesundheitsdiensts) unwesentlich h&#246;heren Kosten je richtig-positive Diagnose, als ein Screeningpfad bei dem zus&#228;tzlich eine Perimetrie f&#252;r Risikopatienten durchgef&#252;hrt wird, auf. Die eingeschr&#228;nkte medizinische Evidenz zu Screeninguntersuchungen relativiert jedoch dieses Ergebnis. Die kanadische Modellrechnung gibt die Kosten je vermiedenes Jahr Erblindung an; die Autoren lehnen die Einf&#252;hrung eines Glaukomscreenings auf Grund der schlechten Datenlage (Unsicherheit) und der hohen Kosten, die mit diesem Programm verbunden w&#228;ren, ab. </Pgraph>
      <Pgraph>F&#252;r den Vergleich von Screeninguntersuchungen ist der intermedi&#228;re Parameter Kosten pro richtig-positiver Glaukomdiagnose praktikabel. Eine Evaluation eines Glaukomscreenings, die unter Einbeziehung einer Therapiebewertung auf morbidit&#228;tsbezogene Ergebnisparameter zielt, sollte nicht nur das Kriterium der Erblindung, sondern auch Sehbehinderungen ber&#252;cksichtigen. </Pgraph>
      <Pgraph>Aus aktuell laufenden Bewertungen der (medizinischen und) &#246;konomischen Effektivit&#228;t eines Glaukomscreenings (z. B. des britischen &#8222;National Coordinating Centre for Health Technology Assessment&#8220; (NCCHTA)) sind in naher Zukunft Bewertungen auch neuerer Untersuchungsmethoden zu erwarten.</Pgraph>
      <Pgraph>Aus ethischer und juristischer Sicht ist zum gegebenen Zeitpunkt anzumerken, dass in Bezug auf die Erstattung von f&#252;r die Glaukomerkennung relevanten Untersuchungen (Tonometrie und Gonioskopie im Rahmen der Routineuntersuchung und OCT) ein gewisser Graubereich besteht, was speziell f&#252;r &#228;rmere Bev&#246;lkerungsschichten problematisch sein kann. Relevant ist hierbei die Argumentation des Arztes und des Patienten gegen&#252;ber der Krankenkasse, wobei f&#252;r &#196;rzte ein finanzieller Anreiz besteht, diese Leistungen privat als IGeL durchzuf&#252;hren.</Pgraph>
      <SubHeadline>7. Schlussfolgerung&#47;Empfehlung</SubHeadline>
      <Pgraph>Gegenw&#228;rtig kann weder eine einzelne, noch eine Kombination von Untersuchungsmethoden zur Erfassung von POWG mit ausreichender Evidenz empfohlen werden. Die Erkennungsg&#252;te einzelner Methoden ist zu gering, um sie allein einsetzen zu k&#246;nnen. Als sinnvolle Kombination von Methoden kann eine funktionelle Untersuchung (am ehesten die FDT-Perimeterie) mit einer morphometrischen Methode (wie beispielsweise ophthalmoskopische Untersuchung, Scanning-Laser-Tomographie oder die Scanning-Laser-Polarimetrie) gelten. Die fr&#252;her zum Screening vorgeschlagene Tonometrie ist aufgrund der geringen Sensitivit&#228;t nicht allein einsetzbar, jedoch kann sie aufgrund der hohen Spezifit&#228;t ebenfalls sinnvolles Element in einem Screeningalgorithmus sein. Es gibt auch Hinweise f&#252;r den sinnvollen Einsatz einfacher Untersuchungen, wie Sehsch&#228;rfenbestimmung und Erhebung der Familienanamnese. </Pgraph>
      <Pgraph>Es muss die Aufgabe von zuk&#252;nftigen Studien sein, die sinnvollste Auswahl der Methoden bez&#252;glich Kombination und Reihenfolge zu ermitteln. Hohe Sensitivit&#228;t und Spezifit&#228;t der Methoden sind nicht die einzigen relevanten Parameter bei der Etablierung von Screeningprogrammen. Wesentlich sind auch Verbesserungen beim Management der Patienten. Dazu ist es prinzipiell notwendig, bei den mittels Screening erfassten Glaukompatienten in randomisierten, kontrollierten Interventionsstudien einen Therapieerfolg auf Endpunktparameter (beispielsweise Sehbeeintr&#228;chtigungen) zu beweisen.</Pgraph>
      <Pgraph>Die Frage nach der Kosteneffektivit&#228;t von Screeninguntersuchungen zur Entdeckung eines POWG kann auf Basis publizierter Literatur oder &#220;bertragung von Studienergebnissen auf Deutschland derzeit nicht beantwortet werden. Eine &#246;konomische Evaluation eines medizinisch effektiven Screeningprogramms sollte ber&#252;cksichtigen, dass im Rahmen des Screenings andere Augenerkrankungen erfasst werden k&#246;nnen, deren fr&#252;hzeitige Erkennung medizinisch und &#246;konomisch von Vorteil sein k&#246;nnte, des Weiteren sollten bei Ber&#252;cksichtigung morbidit&#228;tsbezogener Ergebnisparameter nicht nur die Erblindung, sondern auch Sehbehinderungen ber&#252;cksichtigt werden. </Pgraph>
    </TextBlock>
    <Media>
      <Tables>
        <NoOfTables>0</NoOfTables>
      </Tables>
      <Figures>
        <NoOfPictures>0</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
      <AdditionalDocument>hta144&#95;bericht&#95;de.pdf</AdditionalDocument>
    </Media>
  </OrigData>
</GmsArticle>