GMS Hygiene and Infection Control__Temp
Volume 8 (2013)
Issue 2
- Research Article
Evaluation of reprocessing medical devices in 14 German regional hospitals and at 27 medical practitioners‘ offices within the European context – consequences for European harmonization
Thiede B, Kramer AGMS Hyg Infect Control__Temp. 2013;8(2):Doc20 (2013-11-06) - Research Article
Hygienic safety of alcohol-based hand disinfectants and skin antiseptics
Steinhauer K, Meyer B, Ostermeyer C, Rödger HJ, Hintzpeter MGMS Hyg Infect Control__Temp. 2013;8(2):Doc19 (2013-11-06) - Research Article
Improving patient safety during insertion of peripheral venous catheters: an observational intervention study
Kampf G, Reise G, James C, Gittelbauer K, Gosch J, Alpers BGMS Hyg Infect Control__Temp. 2013;8(2):Doc18 (2013-11-06) - Research Article
Serial IGRA testing of trainees in the healthcare sector in a country with low incidence for tuberculosis – a prospective cohort study
Schablon A, Peters C, Diel R, Diner G, Anske U, Pankow W, Ringshausen FC, Nienhaus AGMS Hyg Infect Control__Temp. 2013;8(2):Doc17 (2013-11-06) - Research Article
Comparison between phenotypic and PCR for detection of OXA-23 type and metallo-beta-lactamases producer Acinetobacter spp.
Azimi L, Lari AR, Talebi M, Namvar AE, Jabbari MGMS Hyg Infect Control__Temp. 2013;8(2):Doc16 (2013-11-06) - Research Article
Contribution of AcrAB efflux pump to ciprofloxacin resistance in Klebsiella pneumoniae isolated from burn patients
Pakzad I, Zayyen Karin M, Taherikalani M, Boustanshenas M, Lari ARGMS Hyg Infect Control__Temp. 2013;8(2):Doc15 (2013-11-06) - Letter to the Editor
Level of respiratory protection against influenza virus
Joob B, Wiwanitkit VGMS Hyg Infect Control__Temp. 2013;8(2):Doc14 (2013-11-06)
Issue 1
- Editorial
GMS Hygiene and Infection Control
Kramer A, Assadian O, Kohnen WGMS Hyg Infect Control__Temp. 2013;8(1):Doc13 (2013-04-29) - Research Article
One-day point prevalence of emerging bacterial pathogens in a nationwide sample of 62 German hospitals in 2012 and comparison with the results of the one-day point prevalence of 2010
Wegner C, Hübner NO, Gleich S, Thalmaier U, Krüger CM, Kramer AGMS Hyg Infect Control__Temp. 2013;8(1):Doc12 (2013-04-29) - Research Article
Questionnaire-based survey on structural quality of hospitals and nursing homes for the elderly, their staffing with infection control personal, and implementation of infection control measures in Germany
Kramer A, Assadian O, Helfrich J, Krüger C, Pfenning I, Ryll S, Perner A, Loczenski BGMS Hyg Infect Control__Temp. 2013;8(1):Doc11 (2013-04-29) - Consensus Paper
The role of surface disinfection in infection prevention
Gebel J, Exner M, French G, Chartier Y, Christiansen B, Gemein S, Goroncy-Bermes P, Hartemann P, Heudorf U, Kramer A, Maillard JY, Oltmanns P, Rotter M, Sonntag HGGMS Hyg Infect Control__Temp. 2013;8(1):Doc10 (2013-04-29) - Research Article
Can breathing circuit filters help prevent the spread of influenza A (H1N1) virus from intubated patients?
Heuer JF, Crozier TA, Howard G, Quintel MGMS Hyg Infect Control__Temp. 2013;8(1):Doc09 (2013-04-29) - Research Article
Is routine replacement of i.v. administration sets required after each change of intermittently administrated antibiotic infusions?
von Au F, Ryll S, Wegner C, Gessner S, Kramer AGMS Hyg Infect Control__Temp. 2013;8(1):Doc08 (2013-04-29) - Research Article
Microbial contamination of manually reprocessed, ready to use ECG lead wire in intensive care units
Lestari T, Ryll S, Kramer AGMS Hyg Infect Control__Temp. 2013;8(1):Doc07 (2013-04-29) - Research Article
Prospective pilot study on the incidence of infections caused by peripheral venous catheters at a general surgical ward
Heinrich I, Geßner S, Wegner C, Heidecke CD, Kramer AGMS Hyg Infect Control__Temp. 2013;8(1):Doc06 (2013-04-29) - Research Article
Silver nanoparticles as active ingredient used for alcohol-free mouthwash
Fattahi-Dolatabadi M, Mehrabian S, Asghari B, Namvar AE, Ezzatifar F, Lari ARGMS Hyg Infect Control__Temp. 2013;8(1):Doc05 (2013-04-29)With Erratum (2016-03-14) - Research Article
High resistance of Pseudomonas aeruginosa to paromomycin, an agent used for selective bowel decontamination (SBD)
Daxboeck F, Rabitsch W, Stadler M, Assadian O, Leitgeb JGMS Hyg Infect Control__Temp. 2013;8(1):Doc04 (2013-04-29) - Research Article
Detection of the intercellular adhesion gene cluster (ica) in clinical Staphylococcus aureus isolates
Namvar AE, Asghari B, Ezzatifar F, Azizi G, Lari ARGMS Hyg Infect Control__Temp. 2013;8(1):Doc03 (2013-04-29) - Research Article
Bacteriology swabs in primary total knee arthroplasty
Haenle M, Podbielski A, Ellenrieder M, Mundt A, Krentz H, Mittelmeier W, Skripitz RGMS Hyg Infect Control__Temp. 2013;8(1):Doc02 (2013-04-29) - Research Article
In vitro efficacy of cold atmospheric pressure plasma on S. sanguinis biofilms in comparison of two test models
Gorynia S, Koban I, Matthes R, Welk A, Gorynia S, Hübner NO, Kocher T, Kramer AGMS Hyg Infect Control__Temp. 2013;8(1):Doc01 (2013-04-29)